A Key Communication Module for Connecting Traditional Industrial Networks
In industrial automation, the coexistence of old and new systems and data interoperability are perennial challenges. The Allen-Bradley 2711P-RN6 communication module is a classic solution from Rockwell Automation addressing this need. Designed specifically for PanelView Plus, PanelView Plus CE, and PanelView Plus 6 series graphical user interfaces (HMIs), it is particularly compatible with terminal devices with screen sizes ranging from 7 inches to 15 inches (models 700-1500). Its core value lies in enabling next-generation HMI products to access the long-established and widely deployed Data Highway Plus, Remote I/O, and DH-485 industrial networks. By installing it on the terminal logic module, PanelView devices, which previously only supported modern network protocols, can seamlessly integrate into existing control system architectures using legacy protocols, effectively protecting user investments in legacy systems, extending the production line lifecycle, and maximizing the utilization of automation assets.

Allen-Bradley 2711P-RN6 Features Clear Technical Specifications and Compatibility

A closer look at the technical details of the 2711P-RN6 reveals a highly targeted and clearly defined design. The module provides two key communication ports: a multi-functional DH+/RIO port and a dedicated DH-485 port, both using reliable Phoenix terminal connectors, equipped with 3-pin and 6-pin interfaces respectively. Regarding protocol support, users should pay special attention to the differences in compatibility with different terminal series. When used with PanelView Plus 6 terminals, the module's Remote I/O function will be disabled, supporting only DH+ and DH-485 communication, due to limitations of the terminal platform itself. Furthermore, this module is explicitly incompatible with newer PanelView Plus 7 series terminals, indicating its applicable product generation range. Its operating temperature range is between 0°C and 55°C, enabling it to adapt to most industrial environments, and it has passed relevant shock and vibration tests, ensuring stable operation under harsh conditions.


Allen-Bradley 2711P-RN6 Ensures Reliable Communication Through Status Indicators and Network Features
Reliability and maintainability are the lifeblood of industrial communication modules. The 2711P-RN6 is equipped with intuitive dual LED status indicators, providing maintenance personnel with clear module and network health diagnostic information. The indicators display various states—off, flashing green, solid green, flashing red, and solid red—representing critical conditions such as device offline, network unique node, online and receiving tokens, address conflict or parity error, and self-test failure, respectively. Regarding network features, it supports DH+/RIO networks using a token passing mechanism, supporting true multi-node communication and trunk distances up to 10,000 feet. The topology is daisy-chained, requiring dedicated twisted-pair cables such as Belden 9463. The DH-485 network also supports daisy-chain topology, allowing a maximum of 32 devices to connect, with a network length of up to 4,000 feet. It uses a master-slave communication mode and supports hot-swapping of devices. These features collectively ensure stable and flexible field communication.


Allen-Bradley 2711P-RN6 Plays a Bridging Role in Modern Industrial Environments

In summary, the 2711P-RN6 module plays an indispensable "bridge" role in modern industrial automation systems. It is not merely a simple physical interface converter, but a communicator between protocols and the times. With its help, the PanelView Plus series terminals, equipped with advanced features such as ActiveX control support, data logging, and remote access, can directly monitor and control classic controllers like PLC-5 and SLC 500 based on DH+ or DH-485 networks, and even manage traditional remote I/O devices. This allows enterprises to ensure continuous acquisition of underlying production data and effective implementation of upper-level monitoring and management during the gradual digital upgrade process. While traditional networks like DH-485 may face performance bottlenecks in the face of increasing data traffic and higher-speed modern industrial Ethernet, the existence of the 2711P-RN6 ensures the integrity and continuity of the entire production system during the transition period, serving as a solid and reliable technological footnote in the evolution of industrial automation.

Recommended model

AI0288
AJ71AP21
AN1030  
AJ61BT11
AJ71C24-S3
AN1030W
AJ65BT-64AD
AJ72P25
ARNI-873A
AJ65BTB1-16D
AJ72R25
AX2003
AJ65SBTB1-32D
AL-20MR-A
AX2003-AS
AJ65SBTB1-32T1
AL2-10MR-A
ATV58HU18N4
AOJ2-E32D
AOJ2E-E56DR
AS-J892-101
AJ71QE71-B5
ARC-PCLU-K
AS-H819-103
AIEX-5862A A-B10
ARNI-796B1
ASGE-1-R2E-AC
ANP101 JW5015-6
ARNI-852E
ARNI-828B7 2N3A2195-E10


Sản phẩm mới
Để lại lời nhắn
Nếu bạn quan tâm đến sản phẩm của chúng tôi và muốn biết thêm chi tiết, vui lòng để lại tin nhắn tại đây, chúng tôi sẽ trả lời bạn trong thời gian sớm nhất.
Nộp

Để lại lời nhắn

Để lại lời nhắn
Nếu bạn quan tâm đến sản phẩm của chúng tôi và muốn biết thêm chi tiết, vui lòng để lại tin nhắn tại đây, chúng tôi sẽ trả lời bạn trong thời gian sớm nhất.

Nhà

Các sản phẩm

tiếp xúc

whatsapp